Broadcom patches third vCenter auth bypass in five months
Broadcom patched a 9.8-rated vCenter vmdir authentication bypass on November 24, five days after fixing an exploited zero-day used by ARMORY CASTLE's BONESAW tool to forge admin tokens.

Event log
- CVE-2026-123903 is a 9.8-rated vmdir authentication bypass patched on November 24, 2026, the third since July.
- Predecessor CVE-2026-123890 was exploited by ARMORY CASTLE using BONESAW to forge SSO admin tokens.
- vCenter 9.1 and 9.0 require updates to 9.1.2 and 9.0.2.0300; vCenter 7.0 needs an extended support contract.
- The advisory covered 23 vulnerabilities, including two critical ESX I/O filter memory corruption bugs.
- Mandiant evidence shows ARMORY CASTLE knew of CVE-2026-123890 before CVE-2026-59309 was disclosed on July 29.
Broadcom has patched CVE-2026-123903, a 9.8-rated authentication bypass in VMware vCenter's directory service, five days after fixing a related zero-day that spies had already exploited. The patch landed on November 24. It is the third vCenter authentication bypass since July.
The flaw sits in vmdir, the component holding the identities behind vCenter's single sign-on. An attacker with network access could bypass authentication in the VMware Directory Service, Broadcom said in its advisory. That matters because vCenter is the console administrators use to run their entire virtual estate. The advisory offered no workaround and did not say whether anyone had exploited the new bug. Treat any vendor claim of no known exploitation as an absence of evidence, not evidence of absence.
Who found it, and what the researcher said
Broadcom credited four separate parties with the report: mochazz of Qianxin's sglab, Qi Qin of depthfirst, VulTeam, and XGTP from ThreatBook. One of the credited researchers, posting as Q7, urged operators to move fast: "Glad to see this published! Critical pre-auth authentication bypass in VMware vCenter (CVE-2026-123903, CVSS 9.8). If you run vCenter, please prioritize patching and restrict access to its management interfaces."
That advice is sound but incomplete. Restricting management interfaces does nothing for an attacker already inside the network perimeter.
What did the predecessor flaw actually cost?
The previous bug, CVE-2026-123890, was fixed on November 20, with Broadcom thanking Mandiant for the report. Google Threat Intelligence Group published research the same day showing the flaw had been used in the wild.
GTIG attributed the attacks to ARMORY CASTLE, formerly tracked as UNC5221, a suspected China-nexus espionage actor. The group deployed a custom tool named BONESAW. It extracted vCenter's signing key, forged administrator tokens, and created a single sign-on administrator account. Logs showed BONESAW ran in early September against a server already patched for CVE-2026-59309, the first vmdir bypass, which Broadcom fixed on July 29.
"Mandiant has evidence that ARMORY CASTLE had knowledge of CVE-2026-123890 prior to the disclosure of CVE-2026-59309 on July 29, 2026," GTIG said. In plain terms: the attackers knew about the second bug before anyone disclosed the first. Assume other undisclosed vmdir flaws exist.
Which versions do you need?
Administrators on vCenter 9.1 and 9.0 must update to 9.1.2 and 9.0.2.0300. If you applied last week's builds, 9.1.1.0200 and 9.0.2.0200, those are now insufficient. Customers on vCenter 8.0 and VMware Cloud Foundation 5.x need 8.0 U3m and 5.2.5, the same fixed versions listed for both advisories. vCenter 7.0 users get no patch at all. They must contact Broadcom and hold an extended support contract.
What else shipped in the advisory?
The advisory covered 23 vulnerabilities across ESX, vCenter, Workstation, Fusion, VMware Tools and Avi Load Balancer. Two additional critical bugs deserve attention:
- CVE-2026-123910: memory corruption in the ESX I/O filter service.
- CVE-2026-123911: memory corruption in the same ESX I/O filter service.
Both could give an attacker with network access code execution on the host.
What should operators do now?
Patch vCenter first, then ESX. The vmdir bugs require only network access, no credentials, and the attackers in this campaign have demonstrated they hold vulnerabilities before public disclosure. Check vCenter logs for the BONESAW tool's September activity window, since patched servers may already carry forged SSO administrator accounts. Five days between patches for flaws in the same component is not a reassuring rhythm. Three bypasses in the same code since July 29 suggests the component, not any single bug, is the problem, and Broadcom has said nothing about architectural fixes to vmdir.
via itnews.com.au (Source)
More from Daniel Okafor
Show full bio
Staff writer covering technology and product news in enterprise information technology and the leaders who run at CIO Monitor.
239 articles
The newsroom digest
One email a day with the stories that matter. No noise.
Cross-references
- VMware patches vCenter zero-day exploited since September
- Active Xen Orchestra flaw opens path to XCP-ng host takeover
- Barracuda confirms active exploitation of two appliance flaws